Abstract

Many existing self-supporting towers are built with constant-width caisson foundations. Due to the increased demand to add more antennas to the towers, and more stringent strength requirements in recently revised design standards, many existing caisson foundations require significant strengthening for additional uplift resistance. Although a number of retrofit design solutions are frequently used in practice, there is a lack of literature providing guidelines for the proper analysis of retrofitted foundations. This study proposes a detailed analysis and design methodology to significantly increase the uplift capacity of existing caissons through the use of helical micro piles and reinforced concrete cap beams. Strut-and-tie models are developed and nonlinear finite element analyses are undertaken to verify the behaviour of the proposed design. The overall design methodology is presented in a case study involving an existing tower. The proposed design has a general applicability and is suitable for applications where there is limited space around the existing foundations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.