Abstract
Abstract The intent of this paper is to investigate the effect of the interturn short circuit fault (ISCF) in rotor on the magnetic flux density (MFD) of turbo-generator. Different from other studies, this work not only pays attention to the influence of the faulty degrees on the general magnetic field, but also investigates the effect of the short circuit positions on the harmonic components of MFD. The theoretical analysis and the digital simulation through the FEM software Ansoft are performed for a QSFN-600-2YHG turbo-generator. Several significant formulas and conclusions drawn from the analysis and the simulation results are obtained to indicate the relation between the harmonic amplitude of the MFD and the faulty degree (via nm , the number of the short circuit turns), and the relation between the MFD harmonic amplitude and the faulty position (via αr , the angle of the two slots in which the interturn short circuit occurs). Also, the developing tendency of the general magnetic field intensity, the distribution of the magnetic flux lines, and the peak-to-peak value of MFD are presented.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.