Abstract

It is shown how it is possible to improve the performance of thermal enclosures by using a compensating system. It is also shown that because of the thermal network between the outside temperature, the temperature sensor and the device to be regulated, the latter may undergo residual temperature variations which reduce the overall thermal efficiency of the oven. Thermal transfer functions are measured using an experimental setup in which the node temperatures are measured by thermal sensors. By identifying the thermal response of the nodes with the theoretical transfer function under external temperature or heater excitation, the components of the equivalent R-C network can be determined. It is then possible to make use of a compensating system which can eliminate the parasitic static as well as dynamic thermal effects. Validating measurements and experimental results are presented which show the strong improvement achieved by this compensating system as compared to the conventional approach. >

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call