Abstract

The harmonic interference during the operation of rolling stock or EMU is an important interference source of signal system, especially the running track circuit. The harmonic currents in the signal band exceed the limit, which will affect the reliable operation of the track circuit. Analysis of harmonic characteristics based on traction current and the principle of harmonic suppression, a method of harmonic suppression using multiple control strategies is proposed according to the harmonic distribution characteristics of track circuit. Effectiveness of multiple control strategy for harmonic suppression of traction current is verified by simulation analysis and line operation test. The RMS of traction harmonic current can be controlled in the range of 0.3A. The overall performance of the vehicle is optimized and the electromagnetic interference of the track circuit is effectively suppressed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.