Abstract

Past works showed that the degradation of the passive components caused by aging could induce failures of electronic system, including a harmful evolution of electromagnetic compatibility. This paper presents the impact of the accelerated thermal aging on the electromagnetic emission (EME) of a buck DC–DC converter. The experimental analysis indicates that the aging degradation of several passive components (electrolytic capacitor and powder iron inductor) is the main source of EME evolution. Based on experimental measurement and physical analysis, the empirical degradation models of related passive devices are proposed. The overall objective of this study is to predict the electromagnetic emission evolution of a buck DC–DC converter under a thermal aging, by using these passive device degradation models.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.