Abstract

A combined flow over V-notch weir and below contracted rectangular gate was studied and analyzed. The study covered both free and submerged gate flow conditions, under different weir-gate dimensions. These dimensions include notch angle, notch height, gate width and gate height. The experimental data were analyzed and the roles of the different flow and weir-gate parameters are discussed. Based on dimensional analysis and using non-linear regression analysis, discharge equation was developed for both free and submerged gate flows. The developed equation consists of parameters for gate effect, weir effect and interference of the two devices. Equation showed good agreement with the experimental data and covers a wide range of weir-gate parameters and gate flow conditions.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.