Abstract

Based on a single-stage isolated power-factor-corrected power supply (SSIPP or S/sup 2/IP/sup 2/) employing a boost power-factor-correction (PFC) cell, the relationship between the input line voltage and line current of such switching regulators is studied. The conditions for unity power factor are derived. A control scheme to reduce the switch voltage stress while maintaining unity power factor is proposed. Practical implementation of the proposed control scheme is discussed. It is found that, by adding a simple input voltage feedforward to a conventional PWM controller, the switch voltage stress can be much reduced, while keeping the power factor very close to unity. Analysis and experimental results indicate that such a scheme is effective and feasible.