Abstract

As the design methodology of the corrugated steel shear wall (CSSW) has not yet been included in the design standards, this paper presents a step-by-step design procedure based on the corrugated panel-frame interaction (CPFI). To ensure that the plastic hinges occur at the beam ends and not within the beam span or in the columns, a reduced beam section (RBS) connection was used in steel plate shear walls (SPSWs). In this paper, the corrugated steel shear wall with a reduced boundary beam section (RBS-CSSW) is presented as a promising type of lateral-load‐resisting system. Analytical equations were proposed to estimate the strength of RBS-CSSW based on the frame plastic hinge development considering the interactive shear buckling stress in the corrugated panel. The equations of strength estimation for RBS-CSSW were also evaluated by comparing their results with the numerical results of the two models. The comparison showed that the strength based on the proposed analytical equations were accurate (with more than 95% accuracy) compared to the strength from the FE pushover analyses for the two models.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.