Abstract

Single-phase offline switch mode rectifiers (or offline DC-DC converters) face severe component stresses in higher than 10kW applications. The authors show that in three-phase, switch-mode rectifier (SMR) topologies' component stresses are reduced, and performance is improved substantially. These improvements include faster response times, reduced switching stresses of the power semiconductor devices, and reduced size and ratings of associated reactive components. The authors also present an analysis and design approach for three-phase SMR converters under large-input voltage and load variations. Output voltage control is achieved by varying the duty cycle of the inverter power semiconductor switches. Theoretical results are verified experimentally. >