Abstract

This paper presents the analysis and compensation method of the voltage error by a dead-time with a five-leg inverter (FLI). The FLI is the single inverter to drive two three-phase AC motors independently. For the reason that the inverter connects one phase of each motor to a common leg, the voltage error caused by the dead-time will be different in case of a three-phase voltage source inverter (VSI). In case of motor drive with low-speed or using high speed switching devices such as insulated gate bipolar transistor (IGBT), considering about the dead-time voltage error is especially important for reduction of torque ripple. Firstly, the difference of the dead-time voltage error between the three-phase VSI and FLI is theoretically analyzed and discussed in this paper. Second, the dead-time compensation method is introduced. Moreover, the validity of these analyses and compensation method is shown by experimental results.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.