Abstract

Secondary series- and parallel-compensations are widely used in inductive power transfer (IPT) systems for various applications. These compensations are often studied under some isolated constraints of maximum power transfer, optimal efficiency at a particular loading condition, etc. These constraints constitute an insufficient set of requirements for engineers to select appropriate compensation techniques to be used as a voltage converter with optimal efficiency and loading conditions. This paper studies the characteristics of the IPT system at various frequencies of operation utilizing the two compensation techniques to work as a voltage converter. The frequencies that can provide maximum efficiency of operation and load-independent voltage-transfer ratio are analyzed. The optimal frequencies corresponding to the two compensation techniques are found and compared to facilitate the design of voltage converters with efficient power conversion and load-independent frequency of operation. The analysis is supported by experimental measurements.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.