Abstract

In recent years post-tensioned floors are commonly used for parking purposes in residential and commercial high rise buildings. This paper includes result on a study of un-bonded post tensioned cast-in-place parking floor subjected to various arrangements of tendon layout based on FEM analysis. Modelling and analysis of post-tensioned flat plate is done by using SAFE software. Equivalent loads based on cable profiles are applied to the flat plate according to the tendon layout. Design moments, service moments, hyper-static moments, short term deflection, long term deflection, and punching shear are compared for the various tendon layouts at service and ultimate limit state.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.