Abstract

Multi-level neutral-point-clamped (NPC) inverters are widely used in high and medium voltage applications. However, these inverters are only buck-type converters. Recently z-source NPC inverters have been proposed as the buck-boost three-level inverter. New inverters use a z-source network as the input stage. This article analyses the features and limitations of two main topologies of z-source NPC inverters (dual z-source network NPC inverter and single z-source network NPC inverter). The low-frequency ripple of the inductor current and the capacitor voltage of the z-source networks in the z-source NPC inverters are surveyed. This article also proposes two novel PWM methods for the z-source NPC inverters, which can be easily implemented experimentally. In the proposed methods, generated switching signals for the conventional NPC inverter are modified for the z-source NPC inverter using a simple logic circuit considering the boost factors and the power sharing ratio. The performance of the proposed simple PWM methods is verified by simulation and experimental results.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.