Abstract

Analyses were performed on the dispersion overshoot and inverse dissipation of the high-order finite difference scheme using Fourier and precision analysis. Schemes under discussion included the pointwise- and staggered-grid type, and were presented in weighted form using candidate schemes with third-order accuracy and three-point stencil. All of these were commonly used in the construction of difference schemes. Criteria for the dispersion overshoot were presented and their critical states were discussed. Two kinds of instabilities were studied due to inverse dissipation, especially those that occur at lower wave numbers. Criteria for the occurrence were presented and the relationship of the two instabilities was discussed. Comparisons were made between the analytical results and the dispersion/dissipation relations by Fourier transformation of typical schemes. As an example, an application of the criteria was given for the remedy of inverse dissipation in Weirs & Martin’s third-order scheme.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.