Abstract

The edge plasma characteristics are studied by both a movable array of Mach/Reynolds stress/Langmuir 10-probes in the boundary region and the fixed flush probe arrays on the 4 divertor neutralization plates at the same toroidal cross-section in the HL-2A tokamak. The dependence of the Reynolds stress on poloidal flow in the edge plasma is analysed. The result indicates that the sheared poloidal flow in tokamak plasma can be induced by the radial gradient of Reynolds stress. In the divertor experiments of HL-2A, the profiles of the electron temperature, density and floating potential on divertor plates are measured by the flush probe arrays. The edge electron temperature in divertor configuration is higher than that in limiter configuration. The temperature asymmetry between outer and inner target plates is observed. The result of magnetic surface reconstructed from 18 Mirnov coils signals is presented. Both the particle recycling and the impurity flux in the bulk plasma during divertor discharges are discussed. Neutral gas pressure in divertor chamber, measured by fast ionization gauge during divertor discharge, is given.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.