Abstract

AbstractThe paper describes the results of testing six autoclaved aerated concrete (AAC) walls on a natural scale. The walls were made of 18 cm wide blocks and thin layer joints. Reinforced and non‐reinforced walls were tested. Basalt grids and typical steel reinforcement (truss type) were used as reinforcements. The load was applied by a reinforced concrete rim beam. In the first part of the tests, the impact of the opening (window) on stress distribution and the load capacity of the wall was analysed. In the second part of the tests, the unequally loaded connection zone of perpendicular walls was analysed. The results were used to draw practical conclusions on rules of additional reinforcement of zones surrounding openings and connection zones of perpendicular walls.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.