Abstract

In the combustion chamber of PLTU UBOH Banten 3 Lontar uses the waterwall tube (waterwall tube) for heating water to produce high pressure steam and turn a turbine, the heating of them used the principles of radiation and koveksi. Therefore, a problem often encountered is thinning and leaking waterwall tube. Depletion problem waterwall tube is a very urgent issue to be addressed immediately. In this study, the writer focused on the observation and analysis of material failure in the main area of ​​the tube wall material. The writer intends to conduct testing of waterwall tube material with Metallography testing process. The objective of test is to determine the layer thickness and the chemical elements that there is in the material and visual observations of the surface after cleaning which is to determine the level of damage that occurs in the depletion that is caused by shotblasting.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.