Abstract

Heat rate is a measure of the reliability of a generating unit and as the amount of fuel energy required to produce 1 kWh of electrical energy. This study aimed to generator load analysis on the value of heat rate, specific coal consumption and the efficiency of the plant. Heat rate, specific coal consumption and power plant efficiency can be determined by knowing the proximate coal analysis, parameter data from the control room, determine the heat value of coal, power and efficiency of the auxiliary units, NPHR, SCC, the efficiency of the boiler, turbine and power plant. From the data processing are obtained graph generator load to NPHR, SCC and efficiency of the plant. From the calculations, the highest value NPHR of 3580.77 kcal / kWh when the load of 29.86 MW, the highest value of SCC of 0.60 kg / kWh when the load is 29.86 MW power plant and the highest efficiency of 33.54% when the load 47, 8 MW. So the higher the value of the generator load NPHR and SCC will be smaller, while efficient the power plant will increase.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.