Abstract

LVL Sengon and concrete can be used to form a composite structure of the floor system. Connections between LVL Sengon and concrete on this composite floor system are the weakest part so that a majority of structural damages are concentrated at these joints. This study discusses the lateral resistance of lag screw joints in a composite system of LVL Sengon and precast concrete. The lateral joint resistance was evaluated through quasi-static loading upon double shear test specimens having two screws at every single shear. Variation of the specimens includes precast concrete compressive strength of 20.71 MPa and 25.29 MPa, screw diameter of 6 mm length 101.6 mm and 8 mm length 101.6 mm and 127 mm, and angle of lag screw axis against the wood fiber of 60° and 90°. The result shows that lateral resistance of the test is greater than that of EYM, SNI, and EC5 predictions. Joint failure in this experiment is due to failure in wood fiber along with the occurrence of one up to two plastic hinges in the screw.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.