Abstract

Background: Humeral shaft fractures account for 1% to 3% of all fractures and approximately 20% of all fracture involving the humerus. The prevalence of non-union for diaphyseal humeral fractures has been reported as 1% to 10% after non-surgical and 10% to 15% after surgical management. Various devices used in treatment of humeral diaphyseal non-union are limited contact dynamic compression plates, locking compression plate (LCP), wave plates, humerus interlocking nail (IMN), Ilizarov external fixators and bone graft struts. Case Description: A 68-year-old man reported a humeral shaft fracture on the left side, due to a simple fall. It was reduced and fixed by IMN. He underwent clinical and radiological follow up. Three months after the intervention, due to persistent pain and impaired function of the left shoulder, the nail was removed and a cemented endoprosthesis was implanted. 3 years later, unsatisfied with the results, he came to our attention and was diagnosed an atrophic non-union in the site of the previous humeral shaft fracture. Moreover, the exams showed a rotator cuff insufficiency. It was decided to perform a single-stage intervention to achieve two goals: cure the humeral shaft non-union and restore the function of the left shoulder. The cemented endoprosthesis was removed, followed by an extensive curettage of the non-union site. A reverse prosthesis was implanted, with an extra-long stem used to stabilize the non-union site, as it was an IMN. An allograft was harvested from a cadaver femur and fixed with two metal cerclages. The patient underwent clinical and radiological follow-up. Complete healing was achieved 8 months later. Conclusion: Humeral shaft nonunion still represent a pathology that pose a serious problem to the surgeon. A correct management should include an accurate pre-operative planning, to achieve the best result possible for the patient.

Highlights

  • Humeral shaft fractures account for 1% to 3% of all fractures and approximately 20% of all fracture involving the humerus [1, 2]

  • Various devices used in treatment of humeral diaphyseal non-union are limited contact dynamic compression plates, locking compression plate (LCP), wave plates, humerus interlocking nail (IMN), Ilizarov external fixators and bone graft struts

  • Three months after the intervention, due to persistent pain and impaired function of the left shoulder, the nail was removed and a cemented endoprosthesis was implanted. 3 years later, unsatisfied with the results, he came to our attention and was diagnosed an atrophic non-union in the site of the previous humeral shaft fracture

Read more

Summary

Background

Humeral shaft fractures account for 1% to 3% of all fractures and approximately 20% of all fracture involving the humerus. Case Description: A 68-year-old man reported a humeral shaft fracture on the left side, due to a simple fall. He underwent clinical and radiological follow up. Three months after the intervention, due to persistent pain and impaired function of the left shoulder, the nail was removed and a cemented endoprosthesis was implanted. 3 years later, unsatisfied with the results, he came to our attention and was diagnosed an atrophic non-union in the site of the previous humeral shaft fracture. It was decided to perform a single-stage intervention to achieve two goals: cure the humeral shaft non-union and restore the function of the left shoulder. A correct management should include an accurate pre-operative planning, to achieve the best result possible for the patient

Introduction
Discussion
Conclusion
Findings
Ethical Approval
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.