Abstract

Bioprosthetic valve thrombosis and related embolism are considered extremely unlikely, thus allowing most patients to avoid long-term anticoagulation. There is, however, limited experience in the diagnosis and treatment of such a condition. We present the case of a patient with a porcine mitral bioprosthesis who presented with acute thrombosis with unusual echocardiographic features. A favorable outcome was observed after conventional anticoagulant treatment.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.