Abstract

In the present research work, the state-of-art label-free electrochemical genosensing platform was developed based on the hybridization process in the presence of [Fe(CN)6]3-/4- as an efficient redox probe for sensitive recognition of the miRNA-21 in human gastric cell lines samples. To attain this aim, perovskite nanosheets were initially synthesized. Afterward, the obtained compound was combined with the graphene oxide resulting in an effective electrochemical modifier, which was dropped on the surface of the Au electrode. Then, AuNPs (Gold Nano Particles) have been electrochemically-immobilized on perovskite-graphene oxide/Au-modified electrode surface through the chronoamperometry (CA) technique. Finally, a self-assembling monolayer reaction of ss-capture RNA ensued by the thiol group at the end of the probe with AuNPs on the modified electrode surface. miRNA-21 has been cast on the Au electrode surface to apply the hybridization process. To find out the effectiveness of the synthesized modifier agent, the electrochemical behavior of the modified electrode has been analyzed through DPV (differential pulse voltammetry) and CV (cyclic voltammetry) techniques. The prepared biomarker-detection bioassay offers high sensitivity and specificity, good performance, and appropriate precision and accuracy for the highly-sensitive determination of miRNA-21. Different characterization methods have been used, such as XRD, Raman, EDS, and FE-SEM, for morphological characterization and investigation of particle size. Based on optimal conditions, the limit of detection and quantification have been acquired at 2.94 fM and 8.75 fM, respectively. Furthermore, it was possible to achieve a wide linear range which is between 10-14 and 10-7 for miRNA-21. Moreover, the selectivity of the proposed biosensing assay was investigated through its potential in the detection of one, two, and three-base mismatched sequences. Moreover, it was possible to investigate the repeatability and reproducibility of the related bio-assay. To evaluate the hybridization process, it is important that the planned biomarker detection bio-assay could be directly re-used and re-generated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.