Abstract
In-vitro studies were performed on dentin of extracted human molars to investigate the effectiveness of 9.3μm CO2 laser irradiation to occlude dentinal tubules. The observed occlusion of dentinal tubules with the irradiation was compared with application of three reagents: 2% Sodium Fluoride gel, an aqueous solution of hydroxyapatite nanoparticles and an equal mix of the two. We show that 9.3μm CO2 laser irradiation occludes dentinal tubules, and the use of laser irradiation produces better occlusion of the opened tubules compared to the use of topical reagents. Nine extracted and cleaned human molars were cut to obtain dentin disks of thickness of 3-5mm. Each disc was divided into four quarters, and each quarter served as two samples corresponding to irradiated and non-irradiated group counterparts. Five disks were used to study the effect of various laser irradiation energies on the dentinal tubules to find a good pulse fluence for occlusion of the dentinal tubules, and four disks were used for studying the effects of reagents and irradiation at the pulse fluences found in the first part of the study. The samples were irradiated with a beam diameter of 1mm (1/e2) at 15Hz pulse repetition rate, scanned automatically using a set of scanning mirrors. Samples were imaged using Scanning Electron Microscope (SEM) which were processed to determine tubule diameter. Safety of the irradiation treatment was investigated on 6 samples by measuring pulpal temperature rise. The effect of three topical reagents corresponding to 2% Sodium Fluoride gel (F), Hydroxyapatite nanoparticles (HA) and an equal mix of F and HA (HAF) on dentinal tubule occlusion was evaluated and compared with the laser irradiation. In all examined cases, laser irradiation at a fluence of 0.81J/cm2 resulted in a temperature increase less than 3°C which is safe, and no surface cracking was observed. There is a threshold pulse fluence of 0.27J/cm2 above which, laser produced surface melting. At a pulse fluence of 0.81J/cm2 a layer of recast of melted dentin was formed. Under this layer, peritubular dentin melting and occluding of the dentinal tubules was observed. Application of either F or HA or HAF did not produce visible occlusion effect on open tubules after washing and microbrushing with excess distilled water. 9.3μm CO2 laser irradiation on extracted human molar dentin at pulse fluence of 0.81J./cm2 resulted in tubule area reduction by 97% without rising pulpal temperatures to unsafe levels.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.