Abstract

In order to lower the cost and expand the working range of pulsewidth modulation (PWM)-inverter-fed interior permanent magnet synchronous motor drives, the control methods under the overmodulation mode with only a dc-link current sensor are investigated. The space vector modulation of the PWM inverter is analyzed in detail, and an adjustment scheme for the reference voltage vectors is developed to fulfill the requirements by phase current reconstruction under overmodulation. Furthermore, in order to simplify the control process and reduce the control errors, a specified overmodulation method based on the superposition principle is proposed for the PWM inverter with phase current reconstruction, which overcomes the shortcoming of the PWM adjustment scheme. Experimental results demonstrate the feasibility and the effectiveness of the proposed control method, which realizes the single current sensor overmodulation control with maximum voltage transfer ratio.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.