During the four month period, from December 1988 to March 1989, there was an outbreak of Heinz body positive hemolytic anemia in 34 patients undergoing hemodialysis in a 500-bed hospital, Seoul, Korea. The episodes of hemolysis were not reduced by changing the charcoal column and reverse osmosis system, or by adding ascorbic acid to the dialysate. The concentrations of nitrate, copper, aluminum and zinc in the treated water were all within the standards for hemodialysis. The chloramine concentration of the treated water was over 0.6 mg/L, markedly exceeding the allowable level of 0.1 mg/L. This high level of chloramine was proved to be due to the contamination of the water source by raw sewage. After we changed the source of water supply to another, no more episodes of hemolytic anemia occurred. It is concluded that chloramine is one of the major contaminants causing dialysis-induced hemolytic anemia and regular determinations are necessary, especially during winter and dry seasons.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.