Abstract
Relationships between the plasma concentration of a cathepsin K inhibitor (ONO-5334) and inhibition of bone resorption markers N-telopeptide of type I collagen (NTX) and C-telopeptide of type I collagen (CTX) in serum and urinary NTX/creatinine and CTX/creatinine were examined in 10 postmenopausal women. The subjects received slow-release tablets of 100mg ONO-5534 under fasted or fed conditions in a study with a crossover design. Inhibition of serum NTX and CTX levels and plasma concentrations of ONO-5334 were monitored at 0, 24, 48 and 168h after dosing. Changes in urinary NTX/creatinine and CTX/creatinine levels in second morning urine were evaluated on 0, 1, 2 and 7days after dosing. Data were analyzed using sigmoid maximal drug effect (Emax) models. The maximal inhibition, estimated Emax values, were −31.8% for serum NTX, −53.1% for serum CTX, −67.2% for urinary NTX/creatinine, and −95.2% for urinary CTX/creatinine. The estimated half maximal effective plasma concentrations (EC50) of ONO-5334 and confidence intervals were 1.79 (1.01 to 3.16) ng/mL for serum NTX, 2.07 (1.63 to 2.62) ng/mL for serum CTX, 1.85 (1.30 to 2.61) ng/mL for urinary NTX/creatinine, and 1.98 (0.94 to 3.76) ng/mL for urinary CTX/creatinine. EC50 values for the four crosslinks did not significantly differ, as indicated by the overlapping 95% confidence intervals. The highest signal-to-noise ratio was achieved with serum CTX, and was 2-fold higher than that on serum NTX. Inhibition for serum NTX and CTX, and urinary NTX/creatinine and CTX/creatinine by ONO-5334 were all correlated with correlation coefficients ranging from 0.55 to 0.80. In conclusion, data of ONO-5334 slow-releasing tablets in postmenopausal women were well fitted in Emax model. In all measured telopeptides, the maximal inhibition was obtained at urinary CTX/creatinine level, but serum CTX had the highest signal-to-noise ratio. Inhibition for all measured telopeptides by ONO-5334 were all correlated. The estimated half maximal effective plasma concentrations were not significantly different between all measured telopeptides.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.