Abstract
Background and Objectives: Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. This study aimed to assess the validity, intra-rater, and inter-rater reliability of the VeloFlex system (VS), which is a new camera-based tool designed for tracking joint trajectories and measuring joint ROM. Materials and Methods: Thirty-five healthy volunteers (16 females; aged 18–61 years) participated in this study. All participants were assessed on two separate occasions, one week apart. During the first assessment session, measurements were obtained using a goniometer and the VS, whereas, in the second session, only the VS was used. In each assessment session, nine active movements were examined. For each movement, three trials were tested, and the mean of these three measures was used for analysis. To evaluate the concurrent validity and agreement, the Pearson correlation coefficient (r) and Bland-Altmann plots were used. Intra-rater and inter-rater reliability were evaluated using intra-class correlation (ICC), standard error of measurement (SEM), and minimal detectable change (MDC). Results: Both devices showed excellent correlations for all movements (r ranged from 0.992 to 0.999). The intra-rater reliability of the VS was excellent (ICC ranged from 0.93 to 0.99), SEMs ranged from 0.53% to 2.61% and the MDC ranged from 0.68° to 3.26°. The inter-rater reliability of the VS was also excellent (ICC ranged from 0.88 to 0.98), SEMs ranged from 0.81% to 4.76% and the MDC ranged from 2.27° to 4.42°. Conclusions: The VS is a valid and reliable tool for the measurement of ROM of lower limb joints in healthy subjects.
Highlights
Measurement of range of motion (ROM) plays an important role in the clinical examination of patients with lower limb disorders, such as hip arthroplasty or acute ankle sprain [1,2]
The measurements were performed consecutively with both the VeloFlex system (VS) and the Universal goniometers (UG) in S1, as we examined the concurrent validity while the participants maintained maximal range for three seconds
The results of the ROM extracted in S1 from both the VS and UG instruments are reported in
Summary
Measurement of range of motion (ROM) plays an important role in the clinical examination of patients with lower limb disorders, such as hip arthroplasty or acute ankle sprain [1,2]. The photo capture software available often requires an examiner to mark landmarks on a photo of a joint at the end of ROM. Based on these data, the software calculates the angle of the drawn lines [6]. Within the clinical evaluation of multiple pathologies of the lower limb, the measurement of range of motion (ROM) of its joints is fundamental. To this end, there are various tools, from the goniometer as a reference to more recent devices such as inclinometry-based applications, photo capture applications, or motion capture systems. Results: Both devices showed excellent correlations for all movements
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.