Abstract

We present a data processing algorithm for angular reconstruction and event selection applied to 2-D photoelectron track images from X-ray polarimeters. The method reconstructs the initial emission angle of a photoelectron from the initial portion of the track, which is obtained by continuously cutting a track until the image moments or number of pixels fall below tunable thresholds. In addition, event selection which rejects round tracks quantified with eccentricity and circularity is performed so that polarimetry sensitivity considering a trade-off between the modulation factor and signal acceptance is maximized. The modulation factors with applying track selection are 26.6±0.4, 46.1±0.4, 62.3±0.4, and 61.8±0.3% at 2.7, 4.5, 6.4, and 8.0 keV, respectively, using the same data previously analyzed by Iwakiri et al. (2016), where the corresponding numbers are 26.9±0.4, 43.4±0.4, 54.4±0.3, and 59.1±0.3%. The method improves polarimeter sensitivity by 5%–10% at the high energy end of the band previously presented (Iwakiri et al. 2016).

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.