Abstract

An experimental, optical shaft resolver is described which uses continuously rotating radial gratings to form two light modulators. Angular position is determined as the phase difference between the signals from the fixed reference modulator and the variable position modulator. 360 line gratings are used, each line interval being divided into 200 parts by conventional equipment. The method is able to average centring and manufacturing errors, thus reducing production tolerances.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.