Abstract

This work aims at studying the thermal runaway process caused by thermal abuse using different optical techniques. A commercial Samsung ICR 18,650 – 26 J cylindrical battery cell is exposed to different heating ramps in a Continuous Flow Vessel (CFV) to identify critical phases of the battery thermal runaway. The open volume test bed allows to increase the temperature under controlled conditions and evacuate the released gases, enhancing the visualization of the battery venting and combustion. The venting of the electrolyte and gases is seen around 200 °C. The safety time, defined as time between venting and fire, was around 3 min, with an inverse relation with respect to the heating ramp. The use of fast cameras (schlieren, Natural Luminosity and OH*) allowed to deeply understand the phenomena of liquid electrolyte and generated internal gases venting as well as the combustion process.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.