Abstract

An instrument for measuring the size and concentration of droplets is described. It has the ability to function in calm and low wind conditions. Droplets in the 5–50 μm diameter range are detected optically. The data acquisition and real-time processing systems corresponding to granulometer measurements are presented. Multiple occupation sample volume (MOSV) signals are taken into account in the processing. The error on the measured droplet concentration is less than 10% when the droplet number is less than 300 per cm3. Results of calibration tests of the instrument, as well as industrial wind tunnel and in situ measurements obtained using it, are presented. They show that this device performs satisfactorily for winds up to 10 m s−1.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.