Abstract
PurposeTo present an open‐source software (https://github.com/CHUSRadOncPhys/FluoMV) for monitoring intrafraction motion that is based on the visualization of superimposed contours of projected region‐of‐interests from DICOM RTSTRUCT files on cine‐MV images acquired and displayed in real‐time during radiation therapy delivery. Clinical use with prostate gold fiducial markers is presented.MethodsProjections of regions of interest (ROI) in the reference frame of the electronic portal imaging device are computed offline for different gantry angles before the first treatment fraction. During treatment delivery, the contrast of portal images is automatically adjusted using a histogram equalization algorithm. The projections associated with the current gantry angle are then superimposed on the images in real time. This allows the therapist to evaluate if the imaged structures of interest remain within their respective contours during treatment delivery and to potentially interrupt the treatment if deemed necessary. The spatial accuracy of the method was evaluated by imaging a ball bearing phantom in a set‐up where the position of the projected ROI is highly sensitive to gantry angle errors. The visibility of fiducial markers during one fraction of seven different volumetric modulated arc therapy (VMAT) prostate treatments is characterized.ResultsThe geometric validation showed a negligible systematic error μ < 0.1 mm for the position of the projections. The random errors associated with the time accuracy of the gantry angle readout were characterized by standard deviations σ ≤ 0.6 mm. The VMAT clinical treatments showed that the fiducial markers were frequently visible, allowing for a meaningful clinical use.ConclusionsThe results demonstrate that the method presented is sufficiently accurate to be used for intrafraction monitoring of patients. The fact that this method could be implemented on many modern linacs at little to no cost and with no additional dose delivered to the patients makes this solution very attractive for improving patient care and safety in radiation therapy.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.