Abstract

A new technique for stator resistance (R/sub s/)-based thermal monitoring of small line-connected induction machines is proposed in this paper. A simple device is developed for injecting a small DC signal into line-connected induction machines for estimation of R/sub s/. The proposed DC injection device is capable of intermittently injecting a controllable DC bias into the motor with very low power dissipation. Experimental results under motor startup, load variation, and abnormal cooling conditions verify that the proposed technique provides an accurate estimate of R/sub s/ that is capable of responding to the changes in the motor thermal characteristics, resulting in reliable thermal protection. The proposed technique is a very practical method for thermal protection of small line-connected induction machines that can be implemented with low cost in a motor condition monitoring system.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.