Abstract

Dual-energy computed tomography (DECT) scans objects using two different X-ray spectra to acquire more information, which is also called dual spectral CT (DSCT) in some articles. Compared to traditional CT, DECT exhibits superior material distinguishability. Therefore, DECT can be widely used in the medical and industrial domains. However, owing to the nonlinearity and ill condition of DECT, studies are underway on DECT reconstruction to obtain high quality images and achieve fast convergence speed. Therefore, in this study, we propose an iterative reconstruction method based on monochromatic images (IRM-MI) to rapidly obtain high-quality images in DECT reconstruction. An IRM-MI is proposed for DECT. The proposed method converts DECT reconstruction problem from the basis material images decomposition to monochromatic images decomposition to significantly improve the convergence speed of DECT reconstruction by changing the coefficient matrix of the original equations to increase the angle of the high- and low-energy projection curves or reduce the condition number of the coefficient matrix. The monochromatic images were then decomposed into basis material images. Furthermore, we conducted numerical experiments to evaluate the performance of the proposed method. The decomposition results of the simulated data and real data experiments confirmed the effectiveness of the proposed method. Compared to the extended algebraic reconstruction technique (E-ART) method, the proposed method exhibited a significant increase in the convergence speed by increasing the angle of polychromatic projection curves or decreasing the condition number of the coefficient matrix, when choosing the appropriate monochromatic images. Therefore, the proposed method is also advantageous in acquiring high quality and rapidly converged images. We developed an iterative reconstruction method based on monochromatic images for the material decomposition for DECT. The numerical experiments using the proposed method validated its capability of decomposing the basis material images. Furthermore, the proposed method achieved faster convergence speed compared to the E-ART method.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.