Abstract

A quota-based approach can help grid operators deal with congestions in distribution grids in a non-discriminatory way for customers. The quota limits the maximum feed-in or consumption of a group of flexibility providing units (FPU) within a grid cluster. The novel iterative quota calculation (IQC) method is introduced in this paper. In this approach, the maximal active power limits of the FPU are constantly adapted, and the feasible operating region (FOR) of the grid is computed. The quota is computed from the resulting FORs after ensuring that the FPU operation cannot cause grid instability. The proposed method is compared to a previously developed static approach in a real LV grid. Results show the benefits of adding reactive power to the quota calculation, especially in distribution grids with inadequate reactive power compensation.