Abstract

This paper proposes a correction method, which corrects the actual compressor performance in real operating conditions to the equivalent performance under specified reference condition. The purpose is to make fair comparisons between actual performance against design performance or reference maps under the same operating conditions. Then the abnormal operating conditions or early failure indications can be identified through condition monitoring, which helps to avoid mandatory shutdown and reduces maintenance costs. The corrections are based on an iterative scheme, which simultaneously correct the main performance parameters known as the polytropic head, the gas power, and the polytropic efficiency. The excellent performance of the method is demonstrated by performing the corrections over real industrial measurements.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.