A new technique for detecting incipient inter-laminar insulation failure of laminated stator cores of large generators is proposed in this paper. The proposed scheme is a low flux induction method that employs a novel probe for core testing. The new probe configuration, which uses magnetic material and is scanned in the wedge depression area, significantly improves the sensitivity of fault detection as well as user convenience compared to existing methods. Experimental results from various test generators tested in factory, field, and lab environments under a number of fault conditions are presented to verify the sensitivity and reliability of the proposed scheme.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.