Abstract

Background ContextMethods to improve osseointegration of orthopedic spinal implants remains a clinical challenge. Materials composed of poly-ether-ether-ketone (PEEK) and titanium are commonly used in orthopedic applications due to their inherent properties of biocompatibility. Titanium has a clinical reputation for durability and osseous affinity, and PEEK offers advantages of a modulus that approximates osseous structures and is radiolucent. The hypothesis for the current investigation was that a titanium plasma spray (TPS) coating may increase the rate and magnitude of circumferential and appositional trabecular osseointegration of PEEK and titanium implants versus uncoated controls. PurposeUsing an in vivo ovine model, the current investigation compared titanium plasma-sprayed PEEK and titanium dowels versus nonplasma-sprayed dowels. Using a time course study of 6 and 12 weeks postoperatively, experimental assays to quantify osseointegration included micro-computed tomography (microCT), biomechanical testing, and histomorphometry. Study Design/SettingIn-vivo ovine model. MethodsTwelve skeletally mature crossbred sheep were equally randomized into postoperative periods of 6 and 12 weeks. Four types of dowel implants–PEEK, titanium plasma-sprayed PEEK (TPS PEEK), titanium, and titanium plasma-sprayed titanium (TPS titanium) were implanted into cylindrical metaphyseal defects in the distal femurs and proximal humeri (one defect per limb, n=48 sites). Sixteen nonoperative specimens (eight femurs and eight humeri) served as zero time-point controls. Half of the specimens underwent destructive biomechanical pullout testing and the remaining half quantitative microCT to quantify circumferential bone volume within 1 mm and 2 mm of the implant surface and histomorphometry to compute direct trabecular apposition. ResultsThere were no intra- or perioperative complications. The TPS-coated implants demonstrated significantly higher peak loads at dowel pullout at 6 and 12 weeks compared with uncoated controls (p<.05). No differences were observed across dowel treatments at the zero time-point (p>.05). MicroCT results exhibited no significant differences in circumferential osseointegration between implants within 1 mm or 2 mm of the dowel surface (p>.05). Direct appositional osseointegration of trabecular bone based on histomorphometry was higher for TPS-coated groups, regardless of base material, compared with uncoated treatments at both time intervals (p<.05). ConclusionsThe current in vivo study demonstrated the biological and mechanical advantages of plasma spray coatings. TPS improved histological incorporation and peak force required for implant extraction. Clinical SignificancePlasma spray coatings may offer clinical benefit by improving biological fixation and osseointegration within the first 6 to 12 weeks postoperatively- the critical healing period for implant-based arthrodesis procedures.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call