Abstract
This paper analyzes the zero-voltage switching (ZVS) for all switches in a high-voltage-gain bidirectional DC–DC converter in triangular conduction mode (TCM) operation without any auxiliary components. From the ZVS condition, the reverse inductor current can be derived, and the required dead-time duration between the main switches and SR switches can be determined, which leads to a reduction in the duty cycle loss. Moreover, the relationship between switching frequency and load in TCM operation can be determined, which helps to reduce the peak-to-peak inductor current and reduce the conduction loss at light load. An experimental prototype of a high-voltage-gain bidirectional DC–DC converter is implemented with a maximum output power of 48 W. The result shows the peak efficiency of 97% and 96.8% in the forward and reverse directions, respectively.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Similar Papers
More From: Electronics
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.