Abstract

ABSTRACTThe foundation of all quantitative remote sensing is based on the ability of sensors to convert energy into digital signals. This process requires an understanding of the radiometric and spectral behaviour of the instrument. This information is rarely available for the consumer-grade digital cameras commonly used in unmanned aerial vehicle (UAV) systems. This study measured the spectral and radiometric characteristics of consumer-grade digital cameras in laboratory-based experiments. The spectral characteristics showed broad overlapping spectral bands in the visible and near-infrared wavelengths with spectral band widths between 70 and 100 nm. The radiometric response functions were non-linear in nature. The nonlinearity resulted in the inability of reliable spectral reflectance calculations. When compared to the spectral reflectance values computed from an ASD FieldSpec-3, differences were as high as 42% from the true value with average deviations between 23% and 32%. When characterized, the spectral reflectance values compared more favourably to ASD-computed spectral reflectance.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.