Abstract

The microstructural properties and wear behaviour of AISI H13 steel which had been plasma nitrided at 530 and 550 °C for times between 4 and 100 h have been investigated. The effect of treatment temperature and time on the microstructure have been examined. The wear behaviour of material treated for 4 and 100 h has also been observed. It was seen that a total case depth of 0.55 mm with a hardness of 1000 HV can be achieved in 100 h. However, the white layer thickness is increased to 17 μm while the core hardness is reduced to 480 HV at 550 °C. The wear rate of the sample treated at 550 °C for 100 h is higher than that of the sample treated at 550 °C for 4 h.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.