The effectiveness of different framing systems for three seismically designed steel frame structures subjected to blast loading is investigated. The three faming systems considered are: a moment resisting frame (MRF), a concentrically braced frame (CBF) and an eccentrically braced frame (EBF). The blast loads are assumed to be unconfined, free air burst detonated 15 ft (4.572 m) from one of the center columns. The structures are modeled and analyzed using the Applied Element Method, which allows the structure to be evaluated during and through failure. Failure modes are investigated through a plastic hinge analysis and member failure comparison. Also, a global response analysis is observed through comparison of roof deflections and accelerations. A conclusion of this research is that braced frames provide a higher level of resistance to the blast loading scenario investigated in this research. Both the CBF and EBF had a smaller number of failed members and plastic hinges compared to the MRF. They also had smaller roof deflection and acceleration. The CBF yielded the fewest number of plastic hinges but the EBF had a slightly fewer number of failed members.

Highlights

  • Over the last few decades, terrorist attacks and accidental explosions have brought on a need for research in the area of structural response subjected to blast loading conditions

  • A conclusion of this research is that braced frames provide a higher level of resistance to the blast loading scenario investigated in this research

  • Both the concentrically braced frame (CBF) and eccentrically braced frame (EBF) had a smaller number of failed members and plastic hinges compared to the moment resisting frame (MRF)

Read more

Summary

Introduction

Over the last few decades, terrorist attacks and accidental explosions have brought on a need for research in the area of structural response subjected to blast loading conditions. Lee et al (2011) evaluated a three story moment resisting steel frame structure subjected to initial dynamic blast effects and performed a progressive collapse study of the structure assuming the loss of the column closest to the blast. They found that the strain rate effects from the initial blast deformation need to be taken into account prior to the progressive collapse analysis for it to accurately model the structural response. A comparative study is performed to determine the effectiveness of different seismic resisting systems

Applied Element Method
Blast loading
Building design
Applying the AEM
Applying the blast loads
Results
Comparison of the seismic resisting framing systems
Conclusions
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.