Abstract

An Intermediate Bulk Container (IBC) was punctured during its handling, releasing oil onto soil at an environmentally-sensitive region of Australia. The telehandler did not pierce the plastic of the IBC directly (as was expected) but rather one of the tynes had caught on the underside of the metal base plate, despite numerous controls being in place at time of spill, revealing a previously unreported mechanism for a fluid spill from handling of petroleum hydrocarbons. The diverse investigation team used a root cause analysis (RCA) technique to identify the underlying cause: the inspection process was inadequate with contributing factors of not using a spotter and design of IBC did not anticipate conditions. Engineering controls were put in place as part of the change management process to help prevent spills from occurring from piercing from telehandler tynes on the current project site.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.