Abstract

Safety factor is a useful concept for analyzing the propagation of impulses through cardiac tissue, which may have compromised ion channel function or electrical connectivity. Several formulations for its calculation have been proposed and have proved useful in one dimension; however, as we demonstrate, recent attempts to use the same formulation in multiple dimensions have led to questionable conclusions. In this study, we mathematically analyze the latest formulation of safety factor and explain its puzzling behavior. We propose a new formulation that is suitable for any dimension and can be estimated from experimental measurements. Its applicability is verified in two-dimensional simulations.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.