Abstract

Missing a laparoscopic needle or a dislodged broken piece of a laparoscopic instrument presents a challenge in localizing it. A fragment of a broken instrument is often confined in an area remote from the primary operative side and entrapped in the bowel loop or in the omentum. An abdominal x-ray film identifies a missing part of the instrument intraabdominally; however, it is extremely difficult to find it with a laparoscope. A precise small area and a reference point are needed to establish where the dislodged missing fragment part is. The radiopaque threads from x-ray–detectable sponges were removed and placed on the abdominal skin, creating a net. With the target square determined by radiopaque threads, finding and removing the dislodged missing piece were achieved very expeditiously. This technique to localize a missing piece of a broken laparoscopic instrument intraabdominally is simple, inexpensive, and noninvasive, allowing expeditious removal and saving substantial operative time. (Am J Obstet Gynecol 1997;176:726-7.)

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.