Abstract
Blood samples for vancomycin levels are often drawn too early, leading to potential misinterpretation of results. However, only a few studies describe interventions to reduce mistimed vancomycin levels. We implemented an information technology (IT)-based intervention that provided educational instructions to nurses and determined the percentage of levels drawn too early for 27 months before (n = 6,291) and 14 months after (n = 3,608) the intervention. In addition, we conducted nurse interviews (n = 40) and dataset analysis to assess the root causes of mistimed levels. The percentage of vancomycin timing errors decreased from 39% (2,438/6,291) to 32% (1,137/3,608), though in a time series analysis this decrease was not statistically significant (P = .64). Four common causes of mistimed levels were found: (1) unclear provider orders, (2) scheduling levels to be drawn with morning laboratory tests, (3) lack of communication between providers, and (4) failure to adjust the blood draw in relation to the previous dose. A real-time, IT-based intervention that links the timing of levels with medication administration might have a more substantial impact.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.