Abstract
We report a comparison of rotational energy loss measurements in the same non-oriented Fe–Si laminations carried out by two laboratories Istituto Nazionale di Ricerca Metrologica (INRiM) in Torino, Italy and Wolfson Centre for Magnetics (WCM) in Cardiff, United Kingdom. The measurements were performed on disk samples at magnetizing frequencies between 5 and 200 Hz with controlled circular flux density loci ranging between 0.2 and 1.9 T. Energy loss was measured applying both the fieldmetric and the rate-of-rise of temperature methods. The latter, exploiting the rate of rise of temperature under quasi-adiabatic conditions, is conveniently adopted on approaching magnetic saturation. Results from the two laboratories agree well up to 1.4 T, despite the different physical principles of the fieldmetric vs. rate-of-rise of temperature methods and the different size of sample and measuring areas. The rate-of-rise of temperature method seems to be the natural approach at high induction values.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.