Abstract
A first-order off-diagonal gradiometer was fabricated and tested. The gradiometer consisted of two field pickup coils and a planar DC SQUID (superconducting quantum interference device) with two superconducting loops connected in parallel, two multiturn input coils, and a modulation-feedback coil. The size of the pickup coils was 6*6 mm/sup 2/ with a base line of 8 mm. The overall size of the gradiometer was 15*7.5 mm/sup 2/. The resolution of the magnetic field gradient of the gradiometer increased from 11 to 1.8 pT/m square root Hz (the noise limits), corresponding to the frequencies from 1 Hz to 600 Hz. The resolution became nearly white in a frequency range above 600 Hz. The intrinsic balance of the gradiometer was better than 1000 p.p.m. for the field perpendicular to its plane. >
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.