Abstract

The application of a new system, which combines textile reinforced mortars (TRM) and thermal insulating materials as a means of both structural (including seismic) and energy retrofitting of masonry walls is experimentally investigated in this study. Medium scale tests were carried out on masonry walls subjected to out-of-plane bending. Several parameters were investigated, including the use of fire-resistant versus polymer-based insulating material, one sided versus two-sided insulation and/or TRM jacketing, the position of the TRM and the displacement amplitude of the loading cycles. From the results obtained in this study the authors believe that TRM jacketing may be combined effectively with thermal insulation, which can be fire-resistant too.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.