Abstract

An innovative smart concrete anchorage (SCA) has been developed for monitoring the stress of prestressing (PS) tendons by utilizing smart ultra-high-performance concrete (UHPC). The smart UHPC contained 2 vol% steel fibers and fine steel slag aggregates instead of silica sands. The effects of different electrode materials, arrangements, and connectors on the self-stress sensing capacity of the SCA are discussed. A prototype SCA demonstrated its feasibility and sufficient self-stress sensing capacity to be used in monitoring the prestressing loss of the PS tendon. As the tensile stress of the PS tendon increased from 0 to 1488 MPa, the fractional change in resistivity (FCR) of the prototype SCA, with horizontally paired copper wire electrodes and a plug-in type connector, decreased linearly from 0% to −1.53%, whereas the FCR increased linearly from −1.53% to −0.04% as the tensile stress of the PS tendon decreased from 1488 to 331 MPa.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.